MARC details
000 -LEADER |
fixed length control field |
02395nam a22003017a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
ZW-GwMSU |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20230502103339.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
230502b |||||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
MSU |
Transcribing agency |
MSU |
Description conventions |
rda |
100 ## - MAIN ENTRY--PERSONAL NAME |
Personal name |
LING, Chengpeng |
245 ## - TITLE STATEMENT |
Title |
Application of electrical resistivity tomography to evaluate the variation in moisture content of waste during 2 months of degradation |
264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE |
Place of production, publication, distribution, manufacture |
Verlag |
Name of producer, publisher, distributor, manufacturer |
Springer |
Date of production, publication, distribution, manufacture, or copyright notice |
2013 |
336 ## - CONTENT TYPE |
Source |
rdacontent |
Content type term |
text |
Content type code |
txt |
337 ## - MEDIA TYPE |
Source |
rdamedia |
Media type term |
unmediated |
Media type code |
n |
338 ## - CARRIER TYPE |
Source |
rdacarrier |
Carrier type term |
volume |
Carrier type code |
nc |
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE |
Title |
Environmental earth sciences |
Volume/sequential designation |
Volume , number , |
520 ## - SUMMARY, ETC. |
Summary, etc. |
Moisture content is considered to play an important role in the degradation of municipal solid waste (MSW). The present study was carried out to test the use of electrical resistivity tomography (ERT) to estimate the daily variations in the volumetric moisture content (VMC) during waste degradation. The degradation of MSW in a laboratory-scale reactor was monitored daily by ERT and time domain reflectometry (TDR) over a period of 55 days after the waste was landfilled. The bulk electrical resistivity, normalised to a standard temperature of 25 °C, was compared to the VMC obtained by TDR. The relationship between the bulk electrical resistivity and the VMC was not obvious in the upper unit, because there was a bias in the positions of the ERT and TDR measurements due to the settling of the waste. However, the bulk electrical resistivity depended on the VMC in the lower unit of the reactor. According to a power equation fitted in the lower unit, the 2-D distributions of the VMC are presented. Variations in the VMC reflected the processes of waste degradation and leachate transportation. Furthermore, the volume of water stored in the lower unit of the reactor was calculated and found to be consistent with that estimated from the gravimetric moisture content during waste sampling. The data showed that ERT could be used to estimate the variations in moisture content in the initial period following the landfilling of waste. |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
electrical resistivity tomography |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
moisture content |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
municipal solid waste |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
ZHOU, Qiyou |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
XUE, Yuwei |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
ZHANG, Yuanyuan |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
LI, Rui |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
LIU, Jianguo |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
https://doi.org/10.1007/s12665-012-1715-y |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Library of Congress Classification |
Koha item type |
Journal Article |